01

Led panel light LX-P10120

2021-07-22 19:14:27
Products Details LED PANEL LIGHT Model #: LX-P10120 Features Unique frame design gives infinite imagination and creative ideas; Different color of light contributes to more visual effect; High quality light guide plate ensure the light uniform and soft; Application Product Parameter   ITEM No. Voltage Power PF Lumen LED type RA CCT SIZE LGP PCS/CTN Carton (L*W*H)cm LX-P10120 100-240V 36W >0.9 2880LM 2835SMD 80 3000K/4000K/6500K 100mm*1200mm*9mm  PMMA: 3.0mm 10 135*17.5*25.7CM LX-P10120 100-240V 40W >0.9 3200LM 2835SMD 80 3000K/4000K/6500K 100mm*1200mm*9mm  PMMA: 3.0mm 10 135*17.5*25.7CM
view detail
01

Led panel light LX-P30120 P3060

2021-07-22 19:14:26
Application 1. Commercial and exhibition locations 2. Hotel, shopping mall 3. Conference/meeting room 4. Factory, office, residence 5. School, hospital and other public places Features • Beautiful and clean appearance, easy installation • High quality light guide plate and diffusion plate, ensure the light uniform and soft • Superior die casting aluminum makes good heat dissipation, no heavy metals and  harmful gas, environmental friendly • Adopting outside power supply with wide input voltage, no flicker, no glare, no radiation Product Parameter
view detail
01

Led panel downlight LX-P02

2021-07-22 19:14:25
Features · Beautiful and clean appearance, easy installation · High quality light guide plate and diffusion plate, ensure the light uniform and soft · Superior die casting aluminum makes good heat dissipation, no heavy metals and  harmful gas, environmental friendly · Adopting outside power supply with wide input voltage, no flicker, no glare, no radiation Application 1. Commercial and exhibition locations 2. Hotel, shopping mall 3. Conference/meeting room 4. Factory, office, residence 5. School, hospital and other public places Product Parameter ITEM NO. Installation method SPEC. Voltatge CCT DRIVER Lumen Ra Color size&installation L W H PCS/CTN PL01 Recessed 3W 85-265V 3000-6000K IC Isolated  60LM/W 80 White 85X75X20mm 52.5 33 29 100 4W 85-265V 3000-6000K IC Isolated  60LM/W 80 White 105X95X20mm 54 28 38 100 6W 85-265V 3000-6000K IC Isolated  60LM/W 80 White 120X110X20mm 54 28 38 100 9W 85-265V 3000-6000K IC Isolated  65LM/W 80 White 147X138X20mm 56 31 45 60 12W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 170X168X20mm 56 31 45 60 15W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 200X188X20mm 65 29.5 48 40 18W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 225X208X20mm 65 29.5 48 40 24W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 300X288X20mm 72 32 36 20 PL02 Surface 6W 85-265V 3000-6000K IC Isolated  60LM/W 80 White 120X120X36mm 46.5 28 26.5 40 12W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 170X170X36mm 61 23.5 39.5 30 18W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 225X225X36mm 49 23.5 47 20 24W 85-265V 3000-6000K IC Isolated  70-80LM/W 80 White 300X300X36mm 66 24.5 67 20  
view detail
01

Led panel downlight LX-PL04 PL05

2021-07-22 19:14:24
Features · Beautiful and clean appearance, easy installation · High quality light guide plate and diffusion plate, ensure the light uniform and soft · Leading heat sink design, excelent heat eliminating · No UV or IR radiation · Adopting outside power supply with wide input voltage, no flicker, no glare,no radiation · Great for under-cabinet and other low voltage applications Application 1. Commercial and exhibition locations 2. Hotel, shopping mall 3. Conference/meeting room 4. Factory, office, residence 5. School, hospital and other public places Product Parameter Model Watt Type Led Type Chip Brand LED qty CRI Lumen PF Driver Voltage Size PL04 12W Slim 2835 Sanan 75 ≥70 70lm/W 0.5 isolated 85-265V 120*105*9mm 18W 2835 Sanan 100 ≥70 70lm/W 0.5 isolated 85-265V 170*155*9mm 24W 2835 Sanan 120 ≥70 70lm/W 0.5 isolated 85-265V 225*210*9mm PL05 12W surface 2835 Sanan 60 ≥70 70lm/W 0.95 isolated 85-265V 120*105*9mm 18W 2835 Sanan 100 ≥70 70lm/W 0.95 isolated 85-265V 170*155*9mm 24W 2835 Sanan 120 ≥70 70lm/W 0.95 isolated 85-265V 225*210*9mm  
view detail
01

3000 HOCHIKI style

2021-07-22 19:14:22
Series HPS-SAH, HPS-SAK, HPS-DAH, HPS-DAH/S, HPS-DAK, HPS-DAK/S Manual Non-Coded Pull Station Standard Features • Metal Construction • Enclosed switch with glass rod (included) • 10 Amps @ 120 VAC • Available in: Single Action, Dual Action and Dual Action in Spanish (HPS-DAH/S) • UL, FM, CSFM Listed • Made in USA Description Hochiki America’s Models HPS series pull stations are available in six models: • HPS-SAH single action • HPS-SAK single action with key lock • HPS-DAH dual action • HPS-DAH/S dual action (Spanish) • HPS-DAK dual action with key lock • HPS-DAK/S dual action with key lock (Spanish) Each model is constructed of a solid die cast housing and comes in glossy red. The back switch plate is plated steel. The electrical switch is rated for 10 Amps @ 120 VDC normally open contact rating. All models are connected via terminal block connections. Product Listing Specification Electrical Wiring
view detail
01

3100 MIRCOM style–5156

2021-07-22 19:14:21
METAL FIRE ALARM STATION MS-700 SERIES Features • Single Stage or Dual Stage models • Key resettable • Terminal connectors • Gold plated SPST contacts • Optional auxiliary contacts • High-gloss red enamel fifi nish • Plastic breakrod • Mounts on standard single gang box, Mircom’s BB-700 surface metal backbox or BB-700WP weather proof backbox • Available in English and Bilingual versions Description Mircom’s MS-700 Series Manual Stations provide manual fifi re reporting. These high quality, die-cast metal manual stations are available in either single or dual action confifi gurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the manual station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The MS-700 Series Manual Stations are available in many different confifi gurations as either single or dual-action devices. The MS-701 is a single action, single stage manual station. Model MS-710 is a single stage, dual action manual station. The MS-702 (two stage) is similar to the MS- 701 (single stage) except it contains an additional General Alarm (G.A.) N.O. switch. For safety reasons, the G.A. switch is only accessible after the handle has been pulled. A special key is supplied with each unit. All models are available with key resets, terminal connectors, SPST gold contacts and CAT-30 lock and keys. The units mount on a standard single gang backbox, Mircom’s BB-700 surface metal backbox or BB-700WP weather proof backbox. The MS-700U Series Manual Stations are listed for outdoor applications when used with the BB-700WP. Operation Specifications The manual station shall be Mircom’s MS-700 Series. Operating instructions shall be in raised English or English and French lettering and the unit shall be constructed of high quality die-cast metal and fifi nished in red enamel paint to provide quick identififi cation. Pulling the handle shall initiate immediate operation of the alarm detection circuit. In addition, those stations installed in a two stage system shall come equipped with an internal key switch designed to operate the 2nd stage alarm initiating circuit. All manual fifi re alarm stations shall be installed to comply with the Canadian Electrical Code (CSA 22.1) and CAN/ULC-S524-01 Standard for Installation of Fire Alarm Systems. Final acceptance is subject to the local authority having jurisdiction. Switch Rating: 1 Amp @ 30 VDC, 0.1 Amp @ 125 VAC Manual Station Dimensions: 4.9” H x 3.5” W x 2.0” D Colour: Red with raised white letters, white manual bar with raised black letters. Typical Wiring Diagrams NOTES • Wire as shown so that supervision of connections is maintained • Mount station to 2” x 4” x 2¼” outlet box • Maximum size: No. 12 AWG • For Normally Open operation, cut the NC wire • For Normally Closed operation, cut the NO wire • Switches shown in the Station Closed position Surface Mount Backboxes Ordering Information Model: Description MS-701: Single Stage Single Action Manual Station (Bilingual) MS-702: Dual Stage Single Action Manual Station (Bilingual) MS-705: Single Stage Single Action Manual Station c/w one additional Form “C” (SPDT) Contact (Bilingual) MS-710: Single Stage Dual Action Manual Station (Bilingual) MS-715: Single Stage Dual Action Manual Station c/w one additional Form “C” (SPDT) Contact (Bilingual) Note: Add suffifi x “U” for English only models. MS-707: Single Stage Single Action Manual Station c/w 2 Form “C” Contacts MS-708: Dual Stage Single Action Manual Station c/w 2 Form “C” Contacts and Key Switch BB-700: Series 700 Interior Surface Mount Backbox, Red Finish BB-700: WP Series 700 Weatherproof Surface Mount Backbox, Red Finish
view detail
01

3100 MIRCOM style–5157

2021-07-22 19:14:20
METAL FIRE ALARM STATION MS-710U Features • Dual Action • Key resettable • Terminal connectors • Gold plated SPST contacts • Optional auxiliary contacts • High-gloss red enamel finish • Plastic breakrod • Meets ADA 5 lb. maximum manual-force • Mounts on standard single gang box, Mircom’s BB-700 surface metal backbox or BB-700WP weather proof backbox Description Mircom’s MS-710U Manual Station provides manual fire reporting. This high quality, die-cast metal manual station is a dual action unit with SPST contacts and terminal strip connections. The normally open contact, which closes when the manual station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The MS-710U is available with a CAT-30 lock and keys and mounts on a standard single gang backbox, Mircom’s BB-700 surface metal backbox or BB-700WP weather proof backbox. The MS-710U Manual Station is listed for outdoor applications when used with the BB-700WP. Operation Specifications The manual station shall be Mircom’s MS-710U. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. Switch Rating: 1 Amp @ 30 VDC, 0.1 Amp @ 125 VAC Manual Station Dimensions: 4.9” H x 3.5” W x 2.0” D Color: Red with raised white letters, white manual bar with raised black letters. Surface Mount Backboxes   Typical Wiring Diagram Ordering Information Model Description MS-710U Dual Action Manual Station BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish
view detail
01

3100 MIRCOM style–5165

2021-07-22 19:14:20
EMERGENCY MANUAL STATIONS MS-700U SERIES • Key resettable • Terminal connectors • Gold plated SPDT contacts • High-gloss enamel in Blue and Yellow • Normally Open or Normally Closed Alarm Contacts • Meets ADA 5 lb. maximum manual-force Features Mircom’s MS-700U Emergency Manual Stations are high quality, die-cast metal manual stations that are designed to meet special use requirements. The MS- 700U are designed for indoor and outdoor use. Mircom’s MS-700U Emergency Manual Stations consist of two models. The MS-703U and MS-704U are single action manual stations. The MS-703U is fifi nished in a Blue enamel and the MS-704U is fifi nished in a Yellow enamel. Both models are available with key resets, CAT-30 lock and keys, SPDT contacts and terminal strip connections. The contacts are gold plated to avoid the risk of corrosion. The MS-700U Emergency Manual Stations mount on a standard single gang backbox. Description Operation Switch Rating: 1 Amp @ 30 VDC, 0.1 Amp @ 125 VAC Manual Station Dimensions: 4.9” H x 3.5” W x 2.0” D Colors: Blue or Yellow with raised white letters. White manual bar with raised black letters. Specifications Switch Rating: 1 Amp @ 30 VDC, 0.1 Amp @ 125 VAC Manual Station Dimensions: 4.9” H x 3.5” W x 2.0” D Colors: Blue or Yellow with raised white letters. White manual bar with raised black letters. Typical Wiring Diagram Ordering Information Model Description MS-703U Blue Single Action Emergency Manual Station c/w 2 Form “C” Contacts MS-704U Yellow Single Action Emergency Manual Station c/w 2 Form “C” Contacts
view detail
01

3200 SUMMIT style

2021-07-22 19:14:19
INTELLIGENT ADDRESSABLE MANUAL STATIONS MS-400AD SERIES Features Description Mircom’s MS-400AD Series are single action alarm manual stations. Each manual station, on command from the panel, returns data representing the status of the unit. The addressable manual station has a pair of rotary decimal switches which allows for two digit address setting. Pulling the handle initiates the operation of the addressable module. Resetting is accomplished by inserting a 1/8” screwdriver from the front. The handle, once pulled will remain open and cannot be reset without utilizing the screwdriver. The MS-400AD Manual stations are constructed of durable aluminium and finished in red. An abrasion resistant label with large, raised letters provides clear legible instructions. The model MS-402AD (two stage) is similar to the MS- 401AD (single stage) except it contains an additional General Alarm (G.A.) N.O. switch. For safety reasons, the G.A. switch is only accessible after the handle has been pulled. A special key is supplied with each unit. The model MS-405AD is similar to the MS-401AD except it has an additional N.O. switch. The model MS-407AD is similar to the MS- 401AD except it has an additional N.C. switch. All manual stations can be easily converted from single action to double action station by the addition of the MS-DA double action lever. Operation Engineer Specifications The single action manual station shall be Mircom’s MS-400AD Series. Operating instructions shall be in raised English lettering (and French Lettering for Canadian models) and the unit shall be constructed of extruded aluminium, finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. In addition, those stations installed in a two stage system shall come equipped with an internal key switch designed to operate the 2nd stage alarm initiating circuit. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL or ULC codes, as well as all other applicable national or local codes. Specifications Dimensions: 4.5”H x 3.5”W x 0.75”D Switch Rating: 1 Amp @ 30 VDC, 0.1 Amp @ 120 VAC Dimensions     Wiring Diagram Ordering Information Model Description MS-401AD Intelligent Addressable Single Stage Manual Station MS-402AD Intelligent Addressable Dual Stage Manual Station MS-405AD Intelligent Addressable Single Stage Manual Station with additional N.O. Switch MS-407AD Intelligent Addressable Single Stage Manual Station with additional N.C. Switch MS-DA Double Action Lever Kit (converts any of above to double action stations) Note: Add suffix “U” for U.S.A. Model Manual Stations.
view detail
01

Manual Call Point LX-502

2021-07-22 19:14:18
Manual Call Point Model #: LX-502 Technical Parameters 1. Voltage range: 12V--50VDC 2. Operating current: 3A 3. Operating temperature: -10℃ -- +65℃ 4. Working humidity range: 10%--90% RH 5. Product size: 10.4x9.2 x5.6cm 6. Installation: indoor or dry occasion 7. Push button panel material: glass, can't reuse Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 50x32x45.5CM 36100pcs Parts Description
view detail
01

Manual Call Point LX-503

2021-07-22 19:14:17
Technical Parameters 1. Voltage range: 12V--50VDC 2. Operating current: 3A 3. Operating temperature: -10℃ -- +65℃ 4. Working humidity range: 10%--90% RH 5. Product size: 10.4x9.2 x5.6cm 6. Installation: indoor or dry occasion 7. Push button panel material: glass, can't reuse Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-503 100pcs 50x32x45.5 36100pcs
view detail
01

Manual Call Point LX-505

2021-07-22 19:14:16
Manual Call Point Model #: LX-505 Technical Parameters 1. Voltage range: 9V--24VDC 2. Static current: ≤10mA 3. Alarm current: ≤20mA 4. Operating temperature: -5℃ -- +65℃ 5. Working humidity: 10%--90% RH 6. Product size: 10.4x9.2 x5.6cm 7. Installation: indoor or dry occasion 8. LED indicator: in no-alarm state,green indicator flashing,when alarming red indicator shining Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 50x32x45.5CM 36100pcs Parts Description
view detail