01

Emergency fire blanket LX-BF1212 /1218/1818

2021-07-22 19:14:24
Fire blankets cut off oxygen for fire suppression with no mess.The emergency fire blanket suffocate the fire, then turn off the heat soure.Fire retardant blanket for protection while camping or cooking in the kitchen, home, smoker, grill, boat or car.It can also be used to cover the body over adults, children or pets.   *The fire suppression blanket is made of 100% fiberglass fabric, fiberglass thread, fire resistant tabs.Thickness of cloth is about 0.43mm.Fabric quality is about 430g/sqm.The fireproof blanket is designed to resist temperature up to 550 celsius degrees.   *The fire blanket meets health,safety and environmental protection standard.
view detail
01

Shielded fire alarm cable LX-SF210 /215/225

2021-07-22 19:14:23
We can provide 2 core fire resistant cable.The fire alarm cable is made of two solid bare copper conductors color coded black and red.The cable is shielded with an aluminum tape shield,and has BC drain wire. Jacket is red LSZH material which is low smoke and zero halogen.   The fire alarm cable is LPCB listed item.100 meters length each reel and packed by plastic or woooden reel.
view detail
01

Fire Siren LX-903

2021-07-22 19:14:03
Technical Parameters 1. Voltage: 24VDC (20mA) 2. Voltage: 3.3VDC (20mA) 3. Flash mode: 2 LED alternating lit 4. Flash rate: 1s 5. Flash color: red 6. Working temperature: -10℃--+70℃ 7. Material: ABS 8. Product size: 8.5x8.5 x3cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-903 100pcs 45.5x34x20 129100
view detail
01

Fire Indicator LX-908

2021-07-22 19:14:04
Technical Parameters 1. Working voltage: 12V--24VDC 2. Working current: 40mA 3. Working temperature: -10℃--+65℃ 4. Working humidity: 10%--90%RH 5. Installation: indoor or dry occasion 6. Product size: 8.6x8.6 x2.25cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP  LX-908 100pcs 42x25x19.5 168200
view detail
01

Multifunctional Alarm LX-241

2021-07-22 19:14:01
Technical Parameters 1. Power supply: 6F22 9V battery 2. Static current: 0mA 3. Alarm current: ≤110mA 4. Alarm sonority: ≥100dB 5. Working temperature: -10℃--+55℃ 6. Working humidity: 10%--90%RH 7. Product size: 8.6x8.6 x2.6cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-241 60pcs 37.5x30.5x33 41040
view detail
01

Manual Call Point LX-232

2021-07-22 19:14:02
Technical Parameters 1. Max. voltage: 50V AC/DC 2. Max. current: 3A AC/DC 3. Battery: 23A/12V x 2 4. Working temperature: -10℃--+65℃ 5. Working humidity: 10%--90%RH 6. Alarm sonority: ≥85dB 7. Installation: indoor or dry occasion 8. Product size: 8.9x8.9 x5.3cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-232 50pcs 59x39.5x25 24300
view detail
01

Fire alarm and manual alarm button combination LX-231A

2021-04-29 12:17:14
This fire alarm device is a combination of fire alarm siren and manual call point.The fire alarm is supplied independently by 9V DC battery. When pressing the button panel,the device will sound continuous alarm and light flashes at the same time to remind people to escape from fire. *Voltage:9V DC * Alarm current:100mA *Alarm sonority: ≥100db *Alarm time:30 minutes * Working temperature: -5℃ to+65℃ *Product size:31.4x19.7x9.6cm *Regular packing is each fire alarm is packed into a neutral white box, 10pcs/master carton,customized color box is available if clients have special demand. Practice fire safety: Expose everyone to the sound of the fire alarm in daily life and explain what the sound means and how to operate the fire alarm button if a fire occurs.Discuss in advance two exits from each room and an escape route to the outside from each exit.Teach them to crawl along the floor to stay below dangerous smoke,fumes and gases.Determine a safe meeting place in advance for all members outside the building. What to do in case of fire: 1. Do not be panic,stay calm. 2. Leave the building as quickly as possible.Touch doors to feel if they are hot before opening them.Use and alternate exit if necessary.Crawl along the floor to stay below dangerous smoke, and don’t stop to collect anything. 3. Meet a pre-arranged meeting place outside the building. 4. Call the fire department form outside the building. 5. Do not go back inside a burning building.Wait for the arrival of the fire department. Caution:Always turn off power at main fuse box or circuit breaker before taking troubleshooting action.Do not disconnect battery or AC power to quiet an unwanted alarm.This will remove your protection.Fan the air or open a window to remove smoker or dust.
view detail
01

Sound and Photic Luxury Alarm LX-103

2021-07-22 19:14:00
Technical Parameters 1. Working voltage: 9V--12VDC / 24VDC 2. Current: ≤300mA 3. Alarm sonority: ≥100dB 4. Operating temperature: -10℃--+55℃ 5. Working humidity: 10%-90% RH 6. Anti-jamming intensity: 1V/m (frequency 20--1000MHZ) 7. Installation: clean, dry and non-vibration wall 8. Product size: 31.4x19.7 x7.5cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-103 10pcs 54x34x43 4900pcs
view detail
01

Sound and Photic Alarm LX-102A/B

2021-07-22 19:14:00
Technical Parameters 1. System voltage/current: 9V (sound) / 120mA 9V (flash) / 60mA 2. Operating temperature: 0℃--50℃ 3. Working humidity: <95% RH 4. Alarm sonority: ≥100dB 5. Indicator colour: red, orange, blue 6. Product size: 20.2x11.3 x7.1cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-102A  B 50pcs 60.5x40x42.5 14000
view detail
01

Stand alone heat detector with sound LX-227

2021-06-25 09:07:03
Model LX-227 is a stand alone heat detctor powered by 9V DC battery.This heat detector is designed to detect ambient temperature. When ambient temperature reaches preset value or the temperature flare to rise,the buzzer will sound. The detector is suitable for industrial and civil building where there is explosive and combustible gas. *Explosionproof function,elegant shell,ceiling mounting easily in minutes *Detecting method:rate of rise and reaching alarm temperature 65℃ *The heat detector is power saving.Static current is less than 100uA. Alarm current is 10-15mA.But alarm sonority is higher than 85db at 1meter distance.   *After installing and switching on power,the detector is in operation state.Led indicator flash every 30 seconds.When it detects the ambient temperature is higher than preset alarm value or the temperature flare up to rise,the buzzer will sound.   Installation method:Turn anti-clockwise the detector body and loosen the base.Install the base to installation position.Turn clockwise the body on base.When it is buttoned completely,you will hear”da”sound.
view detail
01

Heat detector with battery LX-227AC/DC

2021-04-29 11:51:55
This heat detector is designed to detect ambient temperature. When ambient temperature reaches preset value or the temperature flare to rise,the buzzer will sound. The detector is suitable for industrial and civil building where there is explosive and combustible gas. *Model LX-227AC/DC can be connected with mains power(110-220V AC). The heat detector has a built-in 9V battery as backup power. It can work normally in the event of a power outage. *Explosionproof function,elegant shell,ceiling mounting easily in minutes *The heat detector is power saving.Static current is less than 100uA. Alarm current is 10-15mA.But alarm sonority is higher than 85db at 1meter distance.   *After installing and switching on power,the detector is in operation state.Led indicator flash every 30 seconds.When it detects the ambient temperature is higher than preset alarm value or the temperature flare up to rise,the buzzer will sound.   Installation method:Turn anti-clockwise the detector body and loosen the base.Install the base to installation position.Turn clockwise the body on base.When it is buttoned completely,you will hear”da”sound.
view detail
01

CO (Carbon Monoxide) Detector LX-202L

2021-07-22 19:13:56
Technical Parameters 1. Power supply: 24VDC 2. Static current: ≤7mA 3. Alarm current: ≤9mA 4. Alarm density: 400PPM 5. Working temperature: -10℃--+50℃ 6. Working humidity: 5%--95%RH 7. Can be connected with system 8. Product size: 10.9x10.9 x5.2cm Packing Data